Control Bits, Flags, and Status Information
Word
Bit(s)
254
15
Inner Board Error Flag
Turns ON when an error occurs in an Inner Board mounted in slot 1 or slot 2. The error code for
slot 1 is stored in AR 0400 to AR 0407 and the error code for slot 2 is stored in AR 0408 to AR
0415.
AR 04
00 to 07
Slot 1 Inner Board Error Code (Hex)
00:
01, 02: Hardware error
10:
32
Normal
Serial Communications Board error
Note Supported on products with lot number of No. 0320* or later.
Reading lot numbers:
...Produced February 3, 2000
0 3 2 0
Production year: Last digit of the year
Production month: 1 to 9, X (10), Y (11), Z (12)
Production day: 01 to 31