Omron CQM1H-SCB41 Operation Manual page 374

Sysmac cqm1h series serial communications board
Hide thumbs Also See for CQM1H-SCB41:
Table of Contents

Advertisement

Visual Inspection System Protocol
Main axis angle
Main axis angle aberration (reserved)
Edge angle
Edge angle (reserved)
Center X, center Y
Center X displacement (reserved), center Y displacement (reserved)
Inclination
Inclination displacement (reserved)
Intersecting point X, intersecting point Y
Intersecting point X displacement (reserved), intersecting point Y displacement (reserved)
Continuous Measurement Execution (Interrupt) (F300)
(Sequence No. 462)
This sequence carries out continuously setting the F300 and stores measurement results in the specified
words. The interrupt notification method is used for the receive data. The interrupt No. is 102.
Send Data Word Allocation (2nd Operand of PMCR)
None.
Receive Data Word Allocation (3rd Operand of PMCR)
Receive data
storage words
Number of receive data words
+0
(Undefined)
+1
(Undefined)
+2
+3
Decimal portion
+4
Integer portion
0
+5
Sign
Decimal portion
+6
+7
Integer portion
+8
Sign
0
Decimal portion
+9
+10
Integer portion
0
+11
Sign
Decimal portion
+12
+13
Integer portion
+14
Sign
0
Decimal portion
+15
+16
Integer portion
0
Sign
+17
Window No.
Evaluation
result
Data 1
Data 2
Data 3
Data 4
Data 5
Appendix L
359

Advertisement

Table of Contents
loading

Table of Contents