Omron CQM1H-SCB41 Operation Manual page 230

Sysmac cqm1h series serial communications board
Hide thumbs Also See for CQM1H-SCB41:
Table of Contents

Advertisement

E5ZE Temperature Controller Write Protocol
Write Control Period (Sequence No. 153)
Writes the control periods and cooling control periods.
Send Data Word Allocation (2nd Operand of PMCR)
First word of
send data
Receive Data Word Allocation (3rd Operand of PMCR)
None.
+0
Number of send data words
+1
(Undefined)
+2
Control period
+3
Cooling control period
+4
Control period
+5
Cooling control period
~
Control period
+16
Cooling control period
+17
Offset
Contents (data format)
+0
Number of send data words
(4 digits BCD)
+1
Unit No. (2 digits Hex)
+2
Channel 0
Control period (4 digits BCD)
+3
Channel 0
Cooling control period
(4 digits BCD)
+4
Channel 1
Control period (4 digits BCD)
+5
Channel 1
Cooling control period
(4 digits BCD)
+16
Channel 7
Control period (4 digits BCD)
+17
Channel 7
Cooling control period
(4 digits BCD)
Unit No.
Channel 0
Channel 1
~
Channel 7
0018 (fixed)
00 to 0F
0001 to 0099
0001 to 0099
0001 to 0099
0001 to 0099
0001 to 0099
0001 to 0099