K3T@ Intelligent Signal Processor Protocol
Receive Data Word Allocation (3rd Operand of PMCR)
None.
Write Set Value H (Continuous Units) (Sequence No. 304)
This sequence writes set value H for continuous units. The word allocation is identical to that of sequence No.
303 (Write Set Value HH (Continuous Units)).
Write Set Value L (Continuous Units) (Sequence No. 305)
This sequence writes set value L for continuous units. The word allocation is identical to that of sequence No.
303 (Write Set Value HH (Continuous Units)).
Write Set Value LL (Continuous Units) (Sequence No. 306)
This sequence writes set value LL for continuous units. The word allocation is identical to that of sequence No.
303 (Write Set Value HH (Continuous Units)).
Write Set Value with Bank (by Unit Number) (Sequence No. 307)
This sequence writes set value of a bank which is not in use (K3TR: HH to LL, K3TC:O1 to O5).
Send Data Word Allocation (2nd Operand of PMCR)
First word of
send data
292
Offset
+0
Number of send data words
(4 digits BCD)
+1
Number of units
(2 digits BCD)
+2 to +3 Set value
(5 digits BCD)
+64 to
Set value
+65
(5 digits BCD)
Number of send data words
+0
+1
(Undefined)
Number of units
+2
(Undefined)
Relevant unit No.
+3
(Undefined)
Operand
+4
+5
Set value
+6
(Undefined)
~
+122
(Undefined)
Relevant unit No.
+123
(Undefined)
+124
Operand
+125
Set value
(Undefined)
+126
Contents (data format)
0004 to 0066
01 to 32
00000 to 99999
Negative sign: F (5th digit BCD)
Example 12345
Same as above
Bank No.
Set value
~
Bank No.
Set value
Appendix I
Data
Example 1234
+2
2345
+2
1234
0001
+3
000F
+3

Advertisement

Table of Contents
loading

Table of Contents