Omron CQM1H-SCB41 Operation Manual page 327

Sysmac cqm1h series serial communications board
Hide thumbs Also See for CQM1H-SCB41:
Table of Contents

Advertisement

V500/V520 Bar Code Reader Protocol
Note Selecting the values marked with asterisks is required for this protocol.
Receive Data Word Allocation (3rd Operand of PMCR)
None.
312
Offset
Contents (data format)
+0
Number of send data words
(4 digits BCD)
+1
Operation mode
(ASCII 1 character)
In-zone control
(ASCII 1 character)
+2
Bar code type
(ASCII 1 character)
+3
Number of digits
(2 digits BCD)
+4
Modulus check
(ASCII 1 character)
+5
Number of matches
(1 digit BCD)
Multistep labels
(1 digit BCD)
+6
Buzzer
(ASCII 1 character)
Horizontal control mode
(ASCII 1 character)
Data
0007 (fixed)
41 ('A'): ONLINE
*42 ('B'): ONLINE CONTROL
*41 ('A'): ON
42 ('B'): OFF
41 ('A'): JAN
42 ('B'): NW7 NORMAL
43 ('C'): NW7 SMALL
44 ('D'): NW7 HEX
45 ('E'): CODE39 NORMAL
46 ('F'): CODE39 ST/SP OUTPUT
47 ('G'): 2 of 5 (ITF)
48 ('H'): CODE128
49 ('I'):
CODE93
4A ('J'): 2 of 5 (3BAR)
4B ('K'): 2 of 5 (5BAR)
00 to 32
00: Any number of digits allowed.
41 ('A'): No-check
42 ('B'): Modulus 10 (all bar codes)
43 ('C'): Modulus 11 (except JAN)
44 ('D'): Modulus 16 (NW7 only)
45 ('E'): Modulus 43 (CODE39 only)
46 ('F'): Modulus 47 (CODE93 only)
47 ('G'): Modulus 103 (CODE128 only)
1 to 5
1 to 4
41 ('A'): ON for normal read
42 ('B'): ON for no-read
43 ('C'): OFF
41 ('A'): Normal (continuous rotating)
42 ('B'): In-zone startup
Appendix J

Advertisement

Table of Contents
loading