Omron CQM1H-SCB41 Operation Manual page 165

Sysmac cqm1h series serial communications board
Hide thumbs Also See for CQM1H-SCB41:
Table of Contents

Advertisement

CompoWay/F Master Protocol
Broadcast with No Conversion and No Response
(Sequence No. 603)
This sequence broadcasts the specified data beginning with the command code No responses are received
and no conversions are performed on the send data.
Send Data Word Allocation (2nd Operand of PMCR(260))
First word of
send data
Receive Data Word Allocation (3rd Operand of PMCR(260))
None. (Specify a dummy value for the operand, such as #0000.)
150
+0
Number of send data words
(Undefined)
+1
MRC
+2
Number of send bytes
+3
+4
Send data
Offset
Contents (data format)
+0
Number of send data words
(4 digits BCD)
+1
(Undefined)
+2
MRC
(2 digits Hex)
+3
Number of send bytes (4 digits
BCD)
+4
Send data
on
+0
+2
+4
+6 etc.
SRC
0005 to 0128
---
SRC
Set the command code for the required
(2 digits Hex)
service
Number of data bytes from the next
byte after the command code until the
byte just before the ETX.
0 to 492 decimal
The data specified in hexadecimal here
is not converted and the number of
+1
bytes specified in S+3 is sent.
+3
+5
Appendix B
Data

Advertisement

Table of Contents
loading

Table of Contents