3Z4L Laser Micrometer Protocol
Calibration Set (Sequence No. 404)
This sequence calibrates the Laser Micrometer.
Send Data Word Allocation (2nd Operand of PMCR)
First word of send
data
Note 1. For this sequence, both the high and low calibration gauges must be set.
2. The limit value, reference value, and offset value can be set to 3 digits for the integer portion and to
4 digits for the decimal portion.
Receive Data Word Allocation (3rd Operand of PMCR)
None.
Calibration Release (Sequence No. 405)
This sequence releases the calibration of the Laser Micrometer.
Send Data Word Allocation (2nd Operand of PMCR)
None.
Receive Data Word Allocation (3rd Operand of PMCR)
None.
Note This sequence releases both the high and low calibration.
326
+0
Number of send data words
+1
Decimal portion
+2
(Undefined)
Decimal integer portion
+3
Sign
Decimal portion
+4
+5
(Undefined)
(Decimal integer portion)
Sign
+6
Offset
Contents (data format)
+0
Number of send data words
(4 digits BCD)
+1
HC gauge dimension (Deci-
mal portion)
(4 digits BCD)
+2
HC gauge dimension (inte-
ger portion)
(3 digits BCD)
+3
HC gauge dimension (Sign)
(ASCII 1 character)
+4 to +6 LC gauge dimensions
High calibration
gauge dimension
(Undefined)
Low calibration
gauge dimension
(Undefined)
0007 (fixed)
0000 to 9999
000 to 999
if +: 20(' ')
if –: 2D('–')
Same as HC gauge dimensions
Appendix K
Data
Example 123.4567
+1
4 5 6 7
+2
0 1 2 3
+3
2 D 0 0
Example 123.4567
+1
4 5 6 7
+2
0 1 2 3
+3
2 D 0 0

Advertisement