Omron CQM1H-SCB41 Operation Manual page 328

Sysmac cqm1h series serial communications board
Hide thumbs Also See for CQM1H-SCB41:
Table of Contents

Advertisement

V500/V520 Bar Code Reader Protocol
BCR Function Read (V500) (Sequence No. 355)
This sequence reads the settings of functions in the Bar Code Reader.
Send Data Word Allocation (2nd Operand of PMCR)
None.
Receive Data Word Allocation (3rd Operand of PMCR)
Receive data
storage words
+0
Number of receive data words
+1
Operation mode
+2
Types of bar code
Number of digits
+3
(Undefined)
+4
Modulus check
Number of
(Undefined)
+5
matches.
Horizontal control
+6
Buzzer
Offset
Contents (data format)
+0
Number of receive data words
(4 digits BCD)
+1
Operation mode
(ASCII 1 character)
In-zone control
(ASCII 1 character)
+2
Bar code type
(ASCII 1 character)
+3
Number of digits
(2 digits BCD)
+4
Modulus check
(ASCII 1 character)
+5
Number of matches
(1 digit BCD)
Multistep labels
(1 digit BCD)
+6
Buzzer
(ASCII 1 character)
Horizontal control mode (ASCII
1 character)
In-zone control
(Undefined)
(Undefined)
Multistep
labels.
0007 (fixed)
41 ('A'): ONLINE
42 ('B'): ONLINE CONTROL
41 ('A'): ON
42 ('B'): OFF
41 ('A'): JAN
42 ('B'): NW7 NORMAL
43 ('C'): NW7 SMALL
44 ('D'): NW7 HEX
45 ('E'): CODE39 NORMAL
46 ('F'): CODE39 ST/SP Output
47 ('G'): 2 of 5 (ITF)
48 ('H'): CODE128
49 ('I'):
4A ('J'): 2 of 5 (3BAR)
4B ('K'): 2 of 5 (5BAR)
00 to 32
41 ('A'): No-check
42 ('B'): Modulus 10 (all bar codes)
43 ('C'): Modulus 11 (except JAN)
44 ('D'): Modulus 16 (NW7 only)
45 ('E'): Modulus 43 (CODE39 only)
46 ('F'): Modulus 47 (CODE93 only)
47 ('G'): Modulus 103 (CODE128 only)
1 to 5
1 to 4
41 ('A'): ON for normal read
42 ('B'): ON for no-read
43 ('C'): OFF
41 ('A'): Normal (continuous rotating)
42 ('B'): In-zone startup
Appendix J
Data
CODE93
313

Advertisement

Table of Contents
loading

Table of Contents