Omron CQM1H-SCB41 Operation Manual page 176

Sysmac cqm1h series serial communications board
Hide thumbs Also See for CQM1H-SCB41:
Table of Contents

Advertisement

E5@K Digital Controller Read Protocol
Receive Data Word Allocation (3rd Operand of PMCR)
Receive data
storage words
Read Hysteresis (Sequence No. 009)
Reads the hysteresis for heating and for cooling and stores the results in the specified words.
Send Data Word Allocation (2nd Operand of PMCR)
First word of
send data
Receive Data Word Allocation (3rd Operand of PMCR)
Receive data
storage words
Read Control Period (Sequence No. 010)
Reads the control period for heating and for cooling and stores the results in the specified words.
Send Data Word Allocation (2nd Operand of PMCR)
First word of
send data
Receive Data Word Allocation (3rd Operand of PMCR)
Receive data
storage words
+0
Number of receive data words
+1
Manual reset value
Offset
Contents (data format)
+0
Number of receive data words
(4 digits BCD)
+1
Manual reset value (4 digits BCD)
Number of send data words
+0
+1
(Undefined)
Offset
Contents (data format)
+0
Number of send data words
(4 digits BCD)
+1
Unit No. (2 digits BCD)
+0
Number of receive data words
+1
Hysteresis (heating)
Hysteresis (cooling)
+2
Offset
Contents (data format)
+0
Number of receive data words
(4 digits BCD)
+1
Hysteresis (heating)
(4 digits BCD)
+2
Hysteresis (cooling)
(4 digits BCD)
Number of send data words
+0
(Undefined)
+1
Offset
Contents (data format)
+0
Number of send data words
(4 digits BCD)
+1
Unit No. (2 digits BCD)
Number of receive data words
+0
+1
Control period (heating)
Control period (cooling)
+2
Offset
Contents (data format)
+0
Number of receive data words
(4 digits BCD)
+1
Control period (heating)
(4 digits BCD)
+2
Control period (cooling)
(4 digits BCD)
0002
0000 to 1000
Unit No.
0002 (fixed)
00 to 31
0003
0001 to 9999
0001 to 9999
Unit No.
0002 (fixed)
00 to 31
0003
0001 to 0099
0001 to 0099
Appendix C
Data
Data
Data
Data
Data
161

Advertisement

Table of Contents
loading

Table of Contents