K3T@ Intelligent Signal Processor Protocol
Sequence
Communications
No.
sequence name
321
Read set value LL (con-
tinuous units)
322
Read set value with bank
(by unit number)
323
Read set value HH with
bank (continuous units)
324
Read set value H with
bank (continuous units)
325
Read set value L with
bank (continuous units)
326
Read set value LL with
bank (continuous units)
327
Read set value O5 with
bank (continuous units)
328
Read set value O4 with
bank (continuous units)
329
Read set value O3 with
bank (continuous units)
330
Read set value O2 with
bank (continuous units)
331
Read set value O1 with
bank (continuous units)
332
Read holding data (by
unit number)
333
Read holding data PH
(continuous units)
334
Read holding data BH
(continuous units)
335
Read display value (PV)
(by unit number)
336
Read display value (PV )
(continuous units)
337
Read model (by unit
number)
338
Read model (continuous
units)
339
General-purpose com-
mand
Note 1. Special specifications are required to use communications + comparison output.
2. Special specifications are required to use communications + comparison output for the K3TR and
K3TC. The operands HH, H, L, and LL are for the K3TR, and the operands O5, O4, O3, O2, and O1
are for the K3TC.
3. Not available for the K3TC.
4. Ladder Interface Settings
YES: User settings are required for the 2nd and 3rd operands of PMCR.
NO:
Send word allocation:
Receive word allocation: Set the constant 0000 for the 2rd operand (S).
286
Function
Reads the set value LL.
Reads set value of a bank which is
not in use (K3TR: HH to LL, K3TC:
O1 to O5).
Reads the set value HH of a bank
which is not in use.
Reads the set value H of a bank
which is not in use.
Reads the set value L of a bank
which is not in use.
Reads the set value LL of a bank
which is not in use.
Reads the set value O5 of a bank
which is not in use.
Reads the set value O4 of a bank
which is not in use.
Reads the set value O3 of a bank
which is not in use.
Reads the set value O2 of a bank
which is not in use.
Reads the set value O1 of a bank
which is not in use.
Reads the peak/bottom data (max-
imum, minimum).
Reads the peak data (maximum).
Reads the bottom data (minimum).
Reads the display value (PV).
Reads the display value (PV).
Reads the model data.
Reads the model data.
Send specified data or receives
specified data and writes it to the
receive data words.
Set a dummy word address for the 3rd operand (D).
Ladder interface
Send word
Receive word
allocation
allocation
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Appendix I
Notes
See
Note1
See
Note2
See
Note1
See
Note1
See
Note1
See
Note1
See
Note1
See
Note1
See
Note1
See
Note1
See
Note1
See
Note3
See
Note3
See
Note3