K3T@ Intelligent Signal Processor Protocol
Model Data Read (Continuous Units) (Sequence No. 338)
This sequence reads model data for continuous units.
Send Data Word Allocation (2nd Operand of PMCR)
First word of
send data
Note The number of Units can be up to 25 maximum.
Receive Data Word Allocation (3rd Operand of PMCR)
The work allocation is similar to sequence No. 337 (Model Data Read (by Unit Number)).
304
Offset
Contents (data format)
+0
Number of receive data words
(4 digits BCD)
+1 to
Input specifications (ASCII 3 charac-
+ 2
ters)
+2
Display specifications (ASCII 1 charac-
ter)
+3
Output specifications (ASCII 2 charac-
ters)
+4
Input contents
(ASCII 2 characters)
+5
Operation mode
(ASCII 2 characters)
+125
Operation mode
(ASCII 2 characters)
Number of send data words
+0
+1
(Undefined)
Number of units
Offset
Contents (data format)
+0
Number of send data words
(4 digits BCD)
+1
Number of units
(2 digits BCD)
0006 to 0126
544131 ("TA1") (K3TH)
544231 ("TB1") (K3TH)
564432 ("VD2") (K3TX)
414432 ("AD2") (K3TX)
564132 ("VA2") (K3TX)
414132 ("AA2") (K3TX)
524231 ("RB1") (K3TR, K3TC)
41 ("A") (common)
42 ("B") (K3TH, K3TX)
43 ("C") (K3TR, K3TC)
5331 ("S1") (RS-232C)
5332 ("S2") (RS-485)
5333 ("S3") (RS-422A)
5335 ("S5") (RS-485 + comparison output)
5336 ("S6") (RS-422A + comparison out-
put)
Leftmost digit: 30 ("0") to 31 ("1")
Rightmost digit: 31 ("1") to 45 ("E")
3030 ("00") (K3TH, K3TX)
3031 ("00") to 3133 ("12") (K3TR)
5542 ("UB") (K3TC)
5543 ("UC") (K3TC)
Same as above
0002
01 to 25