Visual Inspection System Protocol
General-purpose Command (Send/Receive) (Sequence No. 495)
This sequence can set and execute commands that are not otherwise supported. The delimiter (CR+LF) is
automatically attached to the send data.
Send Data Word Allocation (2nd Operand of PMCR)
First word of
send data
Receive Data Word Allocation (3rd Operand of PMCR)
The reception data is stored in the reception data words without the delimiter (CR+LF),
Receive data
storage words
Note 1. The processing depends on the command.
2. For a command with a response, use sequence #495.
366
Number of send data words
+0
Command length
+1
+2
(Undefined)
~
Offset
Contents (data format)
+0
Number of send data words
(4 digits BCD)
+1
Command length (4 digits BCD)
+2 to
Command (ASCII)
Number of receive data words
+0
Command length
+1
(Undefined)
Command
+2
~
Offset
Contents (data format)
+0
Number of receive data words
(4 digits BCD)
+1
Command length (4 digits BCD)
+2 to
Command (ASCII)
Command
~
0003 to 0129
0001 to 0253
Specify ASCII data.
~
ASCII data is returned.