Omron CQM1H-SCB41 Operation Manual page 221

Sysmac cqm1h series serial communications board
Hide thumbs Also See for CQM1H-SCB41:
Table of Contents

Advertisement

E5ZE Temperature Controller Read Protocol
Read Output Value Change Rate Limit (Sequence No. 118)
Reads the output value change rate limits and stores the results in the specified words.
Send Data Word Allocation (2nd Operand of PMCR)
First word of
send data
Receive Data Word Allocation (3rd Operand of PMCR)
Receive data
storage words
206
Offset
Contents (data format)
+0
Number of receive data words
(4 digits BCD)
+1
Channel 0
Output value lower limit
(4 digits BCD)
+2
Channel 0
Output value upper limit
(4 digits BCD)
+3
Channel 0
Cooling control output value upper limit
(4 digits BCD)
+4
Channel 0
Cooling control output value upper limit
(4 digits BCD)
+31
Channel 7
Cooling control output value upper limit
(4 digits BCD)
+32
Channel 7
Cooling control output value upper limit
(4 digits BCD)
Number of send data words
+0
(Undefined)
+1
Unit No.
Offset
Contents (data format)
+0
Number of send data words
(4 digits BCD)
+1
Unit No. (2 digits Hex)
Number of receive data words
+0
+1
Output value change rate limit
+2
Output value change rate limit
~
Output value change rate limit
+8
Offset
Contents (data format)
+0
Number of receive data words
(4 digits BCD)
+1
Channel 0
Output value change rate limit
(4 digits BCD)
+2
Channel 1
Output value change rate limit
(4 digits BCD)
+8
Channel 7
Output value change rate limit
(4 digits BCD)
0033
0000 to 1000
0000 to 1000
0000 to 1000
0000 to 1000
0000 to 1000
0000 to 1000
0002 (fixed)
00 to 0F
Channel 0
Channel 1
~
Channel 7
0009
0000 to 1000
0000 to 1000
0000 to 1000
Appendix E
Data
Data
Data