Visual Inspection System Protocol
Reference Object Registration Command 2 Execution (F300)
(Sequence No. 464)
This sequence performs a measurement for the input image and updates the reference object data of a desig-
nated window.
Send Data Word Allocation (2nd Operand of PMCR)
First word of send
data
Receive Data Word Allocation (3rd Operand of PMCR)
None.
Illumination Fluctuation Follow Execution (F300)
(Sequence No. 465)
This sequence executes an illumination fluctuation follow.
Send Data Word Allocation (2nd Operand of PMCR)
None.
Receive Data Word Allocation (3rd Operand of PMCR)
None.
Measurement Execution and Positioning (F350)
(Sequence No. 470)
This sequence carries out one measurement and stores the measurement results in the specified words.
Send Data Word Allocation (2nd Operand of PMCR)
None.
Receive Data Word Allocation (3rd Operand of PMCR)
Receive data
storage words
Number of send data words
+0
+1
(Undefined)
Offset
Contents (data format)
+0
Number of send data words
(4 digits BCD)
+1
Window No. (2 digits BCD)
+0
Number of receive data words
Decimal portion
+1
Sign
Integer portion
+2
Decimal portion
+3
Integer portion
Sign
+4
Decimal portion
+5
+6
Sign
0
Integer portion
Window No.
0002
00 to 07
X displacement
Y displacement
Correlation value