Visual Inspection System Protocol
Camera Change (Decrease by 1) (F200/300) (Sequence No. 480)
This sequence decreases the display camera No. by 1.
Send Data Word Allocation (2nd Operand of PMCR)
None.
Receive Data Word Allocation (3rd Operand of PMCR)
None.
Camera Change (Increase by 1) (F200/300) (Sequence No. 481)
This sequence increases the display camera No. by 1.
Send Data Word Allocation (2nd Operand of PMCR)
None.
Receive Data Word Allocation (3rd Operand of PMCR)
None.
Binary Level Modification (F200/300) (Sequence No. 482)
This sequence modifies the binary levels (upper limit and lower limit values) of a designated output No. (F200)
or window number No. (F300).
Send Data Word Allocation (2nd Operand of PMCR)
First word of
send data
Receive Data Word Allocation (3rd Operand of PMCR)
None.
Note Enter values so that the upper limit
Reset (F200/300) (Sequence No. 483)
This sequence resets the F200/F300 (to starting status).
Send Data Word Allocation (2nd Operand of PMCR)
None.
Receive Data Word Allocation (3rd Operand of PMCR)
None.
Scene Switching (Decrease by 1) (Sequence No. 490)
This sequence decreases the scene No. by 1.
Send Data Word Allocation (2nd Operand of PMCR)
None.
Receive Data Word Allocation (3rd Operand of PMCR)
None.
364
Number of send data words
+0
(Undefined)
+1
+2
(Undefined)
Upper limit value
Lower limit value
+3
(Undefined)
Offset
Contents (data format)
+0
Number of send data words
(4 digits BCD)
+1
Window No. (1 digit BCD)
+2
Upper limit value (3 digits BCD)
+3
Lower limit value (3 digits BCD)
lower limit.
Window No.
or Output No.
Data
0004
0 to 7
000 to 255
000 to 255