Visual Inspection System Protocol
Scene Switching (Increase by 1) (Sequence No. 491)
This sequence increases the scene No. by 1.
Send Data Word Allocation (2nd Operand of PMCR)
None.
Receive Data Word Allocation (3rd Operand of PMCR)
None.
Scene Switching (Arbitrary) (Sequence No. 492)
This sequence switches to a designated scene No.
Send Data Word Allocation (2nd Operand of PMCR)
First word of
send data
Receive Data Word Allocation (3rd Operand of PMCR)
None.
Measurement, Inspection Termination (Sequence No. 493)
This sequence terminates the measurement and returns to the home menu.
Send Data Word Allocation (2nd Operand of PMCR)
None.
Receive Data Word Allocation (3rd Operand of PMCR)
None.
General-purpose Command (Send) (Sequence No. 494)
This sequence can set and execute commands that are not otherwise supported. The delimiter (CR+LF) is
automatically attached to the send data.
Send Data Word Allocation (2nd Operand of PMCR)
First word of
send data
Receive Data Word Allocation (3rd Operand of PMCR)
None.
Note 1. The processing depends on the command.
2. For a command with a response, use sequence #495.
+0
Number of send data words
+1
(Undefined)
Offset
Contents (data format)
+0
Number of send data words
(4 digits BCD)
+1
Scene No. (2 digits BCD)
+0
Number of send data words
+1
Command length
+2
(Undefined)
Command
~
Offset
Contents (data format)
+0
Number of send data words
(4 digits BCD)
+1
Command length (4 digits BCD)
+2 to
Command (ASCII)
Scene No.
0002
00 to 15
~
003 to 0129
0001 to 0253
Specify ASCII data.