ES100@ Digital Controller Protocol
Read Time Signal (Sequence No. 251)
Reads time signals from 1 to 10 in the variable area.
Send Data Word Allocation (2nd Operand of PMCR)
First word of
send data
Offset
Contents (data format)
+0
Number of receive data words
(4 digits BCD)
+1
1st unit
Event data 1 (2 digits Hex)
Event data 2 (2 digits Hex)
+2
1st unit
Event data 3 (2 digits Hex)
Event data 4 (2 digits Hex)
+3
1st unit
Event data 5 (2 digits Hex)
Event data 6 (2 digits Hex)
+4
1st unit
Event data 7 (2 digits Hex)
Event data 8 (2 digits Hex)
+5
1st unit
Event data 9 (2 digits Hex)
Event data 10 (2 digits Hex)
+125
25th unit
(max.)
Event data 9 (2 digits Hex)
Event data 10 (2 digits Hex)
+0
Number of send data words
+1
Number of units
+2
(Undefined)
(Undefined)
+3
~
+26
(Undefined)
Offset
Contents (data format)
+0
Number of send data words
(4 digits BCD)
+1
Number of units (4 digits BCD)
+2
1st unit
Unit No. (2 digits BCD)
+3
2nd unit
Unit No. (2 digits BCD)
+26
25th unit
(max.)
Unit No. (2 digits BCD)
Number of units x 5 + 1
00 to FF
00 to FF
00 to FF
00 to FF
00 to FF
00 to FF
00 to FF
00 to FF
00 to FF
00 to FF
00 to FF
00 to FF
Unit No.
1st unit
Unit No.
2nd unit
~
Unit No.
25th unit (max.)
Number of units + 2
0001 to 0025
00 to 31
00 to 31
00 to 31
Appendix H