3Z4L Laser Micrometer Protocol
Note This sequence can be used for the 3Z4L-4000 Series only when pin 8 on DIP switch SW2 is turned ON.
Single Run Measurement Start (4000-series) (Sequence No. 434)
When the sample measurement condition is from 1 to 999, this sequence performs a single run measurement
and requests the measurement results.
Send Data Word Allocation (2nd Operand of PMCR)
None.
Receive Data Word Allocation (3rd Operand of PMCR)
Receive data
storage words
344
Offset
Contents (data format)
+0
Number of receive data
words (4 digits BCD)
+1
Segment number
(1 digit BCD)
+2
Measurement interval num-
ber (1 digit BCD)
+3
Lower limit value (Decimal
portion)
(4 digits BCD)
+4
Lower limit value (Integer
portion)
(3 digits BCD)
+5
Lower limit value (Sign)
(BIN)
+6 to +8 Upper limit value
+9 to
Reference value
+11
+12
Analog output scale number
(1 digit BCD)
+13 to
Forced zero number (ASCII
+15
5 characters)
+16
Data output condition
(1 digit BCD)
+17
Data output timer value
(3 digits BCD)
+18
Number of seconds for latch
timer
(2 digits BCD)
+0
Number of receive data words
+1
Decision result
Decimal portion
+2
+3
(Undefined)
+4
Sign
+5
Decimal portion
+6
(Undefined)
+7
Sign
0019 (fixed)
1 to 5
1 to 7
0000 to 9999
000 to 999
If +: 0
If –: F
Same as lower limit value
Same as lower limit value
0 to 3
5A45524F2B ("ZERO+")
4E4F524D20 ("NORM ")
5A45524F2D ("ZERO–")
0 to 6
000 to 999
00 to 99
Measurement value
Integer portion
(Undefined)
Integer portion
Deviation value
(Undefined)
Appendix K
Data
Example 123.4567
+3
4 5 6 7
+4
0 1 2 3
+5
F 0 0 0

Advertisement

Table of Contents
loading