Removing The Power Cord Tray From A Rack Or Cabinet For An Ex8200 Switch; Installing The Power Cord Tray In A Rack Or Cabinet For An Ex8200 Switch - Juniper EX8208 Hardware Manual

Hide thumbs Also See for EX8208:
Table of Contents

Advertisement

Removing the Power Cord Tray from a Rack or Cabinet for an EX8200
Switch
You can remove the power cord tray from a rack or cabinet. (The remainder of this topic uses "rack" to
mean "rack or cabinet.")
In two-post rack installations, we recommend that you do not remove the power cord tray unless you are
also removing the switch and that you remove the switch before you remove the power cord tray.
NOTE:
The EX8216 switch can be installed only in a four-post rack. Installation in a two-post
rack is not supported.
If you remove the power cord tray before removing the EX8208 switch from a two-post rack, there is no
support for the underside of the switch. This creates a problem if and when you need to remove the switch,
because the chassis has no support once you remove the screws that hold the front-mounting brackets
to the rack. In a four-post rack this is not an issue because the switch rests on the adjustable mounting
brackets.
Before you begin to remove the power cord tray:
Ensure no power cables are resting on or threaded through the power cord tray.
Remove the switch if the switch and power cord tray are installed on a two-post rack. See
an EX8208 Switch from a Rack or Cabinet" on page
Ensure that you have the following parts and tools available to remove the power cord tray:
A Phillips (+) screwdriver, number 1, 2, or 3, depending on the size of your rack mounting screws
To remove the power cord tray:
1. Use the appropriate Phillips (+) screwdriver to remove the four mounting screws that hold the power
cord tray in the rack.
2. Remove the power cord tray and store it in the original switch accessory box for later use.

Installing the Power Cord Tray in a Rack or Cabinet for an EX8200 Switch

The power cord tray is supplied with all EX8200 switches. The power cord tray is optional for four-post
rack or cabinet installation but mandatory for a two-post rack or cabinet installation. (The remainder of
290.