Optical Transmission Test (Oc-192, Oc-48, Oc-12) - Alcatel-Lucent 1665 Installation Manual

Hide thumbs Also See for 1665:
Table of Contents

Advertisement

Ring setup and testing: integration procedures

Optical transmission test (OC-192, OC-48, OC-12)

............................................................................................................................................................................................................................................................
Overview
The following test verifies error-free transmission between nodes.
Transmission test procedure
........................................................................................................................................................................................................................
At the test location, select Performance -> View PM Reports -> OCn Section...
1
........................................................................................................................................................................................................................
Choose CP main-1, Port 1
2
........................................................................................................................................................................................................................
Click Select.
3
........................................................................................................................................................................................................................
Select Time Period: 15-Min, Monitored Date: Current Date and Monitor Level: 0 UP.
4
........................................................................................................................................................................................................................
Click Select All to move all Available Parameters to the Selected Parameters column.
5
........................................................................................................................................................................................................................
Click Apply.
6
Result:
........................................................................................................................................................................................................................
Repeat
7
........................................................................................................................................................................................................................
Repeat
8
........................................................................................................................................................................................................................
Repeat
9
........................................................................................................................................................................................................................
Check off the appropriate box in
10
E
O
N D
........................................................................................................................................................
............................................................................................................................................................................................................................................................
365-372-304R7.1
Issue 1, November 2007
The Response Window indicates no transmission errors.
Step 1
through
Step 6
Step 1
through
Step 7
Step 1
and
Step 8
for each node in the ring.
S
F
T E P S
Optical transmission test (OC-192, OC-48, OC-12)
substituting CP main-2 in
for all 1665 DMX shelves at the test location.
Appendix E, "Installation
Step
2.
checklist".
6 - 1 1

Advertisement

Table of Contents
loading

Table of Contents