Malfunctions - Causes and Remedies
Pos: 68.8 /Überschriften/Überschriften 2/P-T/Störungen an der zentralen Kettenschmierung @ 35\mod_1256199185431_78.docx @ 327048 @ 22 @ 1
16.3

Malfunctions on the central chain lubrication system

Pos: 68.9 /BA/Störungen - Ursachen und Behebung/Rundballenpressen/Tabellarische Auflistung Kettenschmierung @ 240\mod_1395153485543_78.docx @ 1891808 @ @ 1
Malfunction
Low oil consumption
Oil consumption too high
Machine is dry
Pump is not pressed to a full
stroke.
Pos: 68.10 /Layout Module /---------------Seitenumbruch---------------- @ 0\mod_1196175311226_0.docx @ 4165 @ @ 1
340
Possible cause
Low pressure
Oil is too thick
System contaminated
Main pipe torn
Oil too thin
No pressure
System blocked
Oil is too thick, nozzles clogged.
Remedy
Pump works with difficulty, dirt in the
pump area
Clean
Pump is not pressed to a full stroke
Adjust according to the operating
instructions
Pump valve does not close correctly
Remove and clean or replace
Replace with recommended oil
Clean or replace all measuring
valves
Repair or replace
Drive with thicker oil
Reduce the pump stroke
Pump not running
Repair, adjust or replace
Main pipe torn
Repair or replace
System has no oil
Vent the system (see chapter
Central chain lubrication system)
Dirt
Clean the system and clean or
replace all measuring valves.
Pipe jammed
Repair or replace
Replace with recommended oil
Clean nozzles