Menu 4-2 "Manual Sensor Test - Krone Fortima F 1250 Original Operating Instructions

Round baler
Table of Contents

Advertisement

Pos: 52.90 /BA/Info-Center/CCI-ISOBUS-Terminal/CCI-Rundballenpressen/Hauptmenüs/Hauptmenü 4 Service/Menü 4-2 Sensortest Hand Fortima @ 251\mod_1397023672182_78.docx @ 1939053 @ 3 @ 1
8.9.1

Menu 4-2 "Manual sensor test"

4-2
Fig.138
In the manual sensor test, the sensors that are installed on the machine are checked for errors.
In addition, the sensors can be correctly adjusted in the manual sensor test. There is no
guarantee the machine is working correctly until after the sensors have been adjusted.
Caution!
The P.T.O. shaft must not be turning during the sensor test.
Displaying the menu
Main menu 4 "Service" is called.
You can select menu 4-2
highlighted in grey.
Press the rotary potentiometer
Press function key
Selecting the sensor
Select the sensor by pressing the function key
The selected sensor is displayed inversely and is tested.
Setting values:
The minimum and maximum setting values with the sensor alive (metal in front of the sensor)
are shown in the upper part of the bar display. The current setting value (actual value) is
displayed under the bar display.
The distance from the sensor to the metal must be adjusted so that in the alive state the bar is
in the upper mark. Next check whether the bar is in non-alive state in the lower marked area.
Pos: 52.91 /BA/Info-Center/Rundballenpresse/Hauptmenü 4 Service/Zur Einstellung der Sensoren siehe Kapitel Wartung „Einstellung der Sensoren". @ 250\mod_1396968606268_78.docx @ 1938388 @ @ 1
To adjust the sensors, refer to chapter Maintenance "Setting the Sensors".
Pos: 52.92 /Layout Module /---------------Seitenumbruch---------------- @ 0\mod_1196175311226_0.docx @ 4165 @ @ 1