Pos: 50.46.10 /Überschriften/Überschriften 3/A-E/A/Allgemeine Meldungen @ 34\mod_1255443656238_78.docx @ 323714 @ 3 @ 1
7.13.3
General Messages
Pos: 50.46.11 /BA/Info-Center/Rundballenpresse/Alarmmeldungen/3) Allgemeine Meldungen @ 34\mod_1255443585941_78.docx @ 323685 @ @ 1
No.
Figure
A01
A02
A03
A04
A14
A15
Pos: 50.46.12 /BA/Info-Center/Rundballenpresse/Alarmmeldungen/3) Allgemeine Meldungen Zusatz @ 213\mod_1389886432417_78.docx @ 1746963 @ @ 1
A16
A17
Pos: 51 /Layout Module /---------------Seitenumbruch---------------- @ 0\mod_1196175311226_0.docx @ 4165 @ @ 1
Possible cause
–
Fuse in job computer is defective.
–
Short circuit at voltage outputs
+12V2FU_L.
–
Fuse in job computer is defective.
–
Short circuit at voltage outputs
+12V3FU_L.
CAN ERROR
–
The CAN connection between the
control unit and the machine was
interrupted.
–
Loose contact in the connection to the
control unit.
EEPROM error
–
Job computer defective.
Undervoltage
–
Tractor battery is defective.
–
Tractor dynamo is too weak.
–
The 12V supply on the tractor side is
too weak or is not correctly connected
to the tractor battery.
Overvoltage
–
Tractor dynamo is defective.
Access to protected memory slot 0.
–
Defect in job computer.
Access to protected memory slots 0-6.
–
Defect in job computer.
KRONE operation terminal Beta
Description
–
Check the connection for short
circuit and replace the fuse.
–
Check the connection for short
circuit.
–
The fuse regenerates itself after
cooling.
–
Check the CAN connection to the
control unit.
–
Replace job computer.
–
Connect the KRONE connecting
cable directly to the tractor
battery.
–
Check the battery voltage.
–
Check the tractor dynamo.
–
Check the tractor dynamo.
–
Restart job computer (disconnect
power supply from tractor to
machine).
–
Replace job computer.
–
Restart job computer (disconnect
power supply from tractor to
machine).
–
Replace job computer.
141