Pos: 52.108 /BA/Info-Center/CCI-ISOBUS-Terminal/CCI-Rundballenpressen/Hauptmenüs/Hauptmenü 4 Service/Sensor B9/B10 Ballenfestigkeit einstellen _ Fortima F CCI @ 251\mod_1397027780718_78.docx @ 1939363 @ @ 1
Setting sensor B9/B10 bale firmness (Fortima F)
Fig. 140
Caution!
The bale chamber must be open and empty.
If the bar (1) is not inside the rectangle (2) when the bale chamber is open and empty, the
respective sensor (2) must be adjusted mechanically.
To do this:
•
Loosen the sensor and move it in the oblong hole (4) until the bar (1) in the display is inside
the rectangle (2).
•
If necessary, move sensor additionally in the oblong holes (5).
Note
An audio signal will be heard if the bar (1) in the display is inside the rectangle (2).
•
Tighten the screw connections of sensor (3).
Note
Saving is only possible if the bar (1) in the display is inside the rectangle (2).
Saving value:
•
Press function key
The symbol
Pos: 52.109 /Layout Module /---------------Seitenumbruch---------------- @ 0\mod_1196175311226_0.docx @ 4165 @ @ 1
2
1
CC000325
in the upper line indicates that the displayed value is saved.
KRONE ISOBUS Terminal
4
3
FOR00050_1
5
177