Maintenance
Pos: 64.112.18 /Überschriften/Überschriften 3/A-E/D/Druckluftbehälter @ 34\mod_1255593348281_78.docx @ 324372 @ 3 @ 1
13.17.3
Compressed-air reservoir
Pos: 64.112.19 /BA/Wartung/Druckluftbehälter/Druckluftbehälter Bild VP1502 @ 34\mod_1255594168750_78.docx @ 324393 @ @ 1
Fig. 274
Pos: 64.112.20 /BA/Wartung/Druckluftbehälter/Druckluftbehälter_Text 20 Betriebsstunden @ 0\mod_1200293406164_78.docx @ 39343 @ @ 1
The compressed-air reservoir stores the compressed air that is pumped by the compressor.
Therefore condensation water may settle in the compressed air reservoir during operation. The
compressed-air reservoir must be emptied regularly. Specifically, it must be emptied:
•
daily in winter (when being used),
•
otherwise weekly and
•
at least after 20 operating hours.
The drain valve on the bottom of the compressed-air reservoir is used for draining.
•
Switch off and secure the machine.
•
Open the drain valve and allow the condensation to run out.
•
Check the drain valve, clean it and screw it back in.
Note
If the drain valve has a heavy accumulation of dirt or is leaking, it must be replaced by a new
one.
Pos: 64.112.21 /BA/Sicherheit/2. Vorangestellte Warnhinweise/Warnung - Druckluftbehälter beschädigte oder korrodiert - Alte Form @ 275\mod_1404385710309_78.docx @ 2066945 @ @ 1
WARNING!
Risk of injury from corroded or damaged compressed air reservoirs.
Damaged or corroded compressed air reservoirs may burst and cause serious injuries.
•
Observe the inspection intervals according to the maintenance table, see chapter
Maintenance Engine "Maintenance table".
•
Have damaged or corroded compressed air reservoirs replaced immediately by a service
centre.
Pos: 64.113 /Layout Module /---------------Seitenumbruch---------------- @ 0\mod_1196175311226_0.docx @ 4165 @ @ 1
316
RP-A-030