KRONE ISOBUS Terminal
Pos: 52.106 /BA/Info-Center/CCI-ISOBUS-Terminal/CCI-Rundballenpressen/Hauptmenüs/Hauptmenü 4 ServiceSensor B9/B10 Ballendurchmesser einstellen _ Fortima V CCI @ 306\mod_1416318318776_78.docx @ 2381895 @ @ 1
Sensor B9/B10 Adjusting the bale diameter (Fortima V)
Fig. 139
Caution!
The bale chamber must be closed and empty. Front tensioning rocker must be positioned flush
with the stop.
If the bar (1) is not inside the rectangle (2) when the bale chamber is closed and emptied, the
corresponding sensor (7) must be adjusted mechanically.
To do this:
•
Loosen the sensor (7) and turn it in the oblong hole until the bar (1) is positioned inside the
rectangle (2) on the bar display.
Note
An audio signal sounds if the bar (1) is inside the rectangle (2).
•
Tighten the sensor (7).
Note
Saving is only possible if the bar (1) is inside the rectangle (2) in the bar display.
Storing a value:
•
Press the
The
icon in the top line indicates that the displayed value is saved.
Pos: 52.107 /Layout Module /---------------Seitenumbruch---------------- @ 0\mod_1196175311226_0.docx @ 4165 @ @ 1
176
7
function key
1
CC000470_1