Venting The Overload Coupling On The Pto Shaft - Krone Fortima F 1250 Original Operating Instructions

Round baler
Table of Contents

Advertisement

Pos: 66.15 /BA/Einlagerung/Rundballenpressen/Überlastkupplung an Gelenkwelle Comprima @ 96\mod_1328790282568_78.docx @ 822224 @ 33 @ 1
15.2.2

Venting the overload coupling on the PTO shaft

Friction clutch only
Fig. 287
Following extended downtimes, overload coupling surfaces (2) may stick to the contact
surfaces.
Vent the overload coupling before use.
Loosen the eight screws (1) to release the spring pressure from the outside washers (3, 4).
Turn the PTO shaft manually.
Tighten the screws until the covering ring (2) is lying directly against the outside washers (3,
4).
Note
Do not tighten the screws (1) too tight. The coupling must still be able to slip.
Then turn the screws (1) one sixth of a revolution back.
Pos: 67 /Layout Module /---------------Seitenumbruch---------------- @ 0\mod_1196175311226_0.docx @ 4165 @ @ 1
4
3
2
1
COM00337
Placing in Storage
335

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fortima f 1250 multicutFortima f 1600Fortima f 1600 multicutFortima v 1500Fortima v 1500 multicutFortima v 1800 ... Show all

Table of Contents