12.4.1 CPU Modules

Error
code
Scan timeout
16#000A
(SM8: The watchdog timer error)
16#000B
The program in the PLC is damaged.
16#000C
The program downloaded to the PLC is incorrect.
16#000D
The CPU parameter is damaged.
The program or the parameter is being downloaded,
16#000E
and therefore the PLC can not run.
16#000F
The original program in the PLC is damaged.
16#0010
The access to the memory in the CPU is denied.
16#0011
The PLC ID is incorrect. (SM9)
16#0012
The PLC password is incorrect.
16#0013
The I/O module can not run/stop. (SM10)
The procedure of restoring the system can not be
16#0014
executed. (SM9)
16#0015
The module table is incorrect. (SM10)
16#0016
The module setting is incorrect. (SM10)
The device which is associated with the data register is
16#0017
incorrect. (SM10)
16#0018
The serial port is abnormal. (SM9)
16#0019
The USB is abnormal. (SM9)
The contents of the system backup file (DUP) are
16#001A
incorrect.
16#001B
Timed interrupt 0 is set incorrectly.
16#001C
Timed interrupt 1 is set incorrectly.
16#001D
Timed interrupt 2 is set incorrectly.
16#001E
Timed interrupt 3 is set incorrectly.
16#001F
The watchdog timer is set incorrectly.
16#0020
The setting of the fixed scan time is incorrect.
16#0021
The setting of the fixed scan time is incorrect.
The CPU parameter downloaded to the PLC is
16#0022
incorrect.
The Y state (STOP->RUN) section in the PLC
16#0023
Parameter Setting window is set incorrectly.
16#0024
There is no I/O module on a backplane.
The initial value of the symbol is not consistant with
16#0025
what is set in the program.
The latching auxiliary relay range which is set is
16#0026
incorrect.
The latching data register range which is set is
16#0027
incorrect.
16#0028
The latching timer range which is set is incorrect.
16#0029
The latching counter range which is set is incorrect.
The latching 32-bit counter range which is set is
16#002A
incorrect.
The latching auxiliary relay range which is set is
16#002B
incorrect.
The communication setting of COM1 is incorrect.
16#0033
(SM9)
The setting of the station address of COM1 is incorrect.
16#0034
(SM9)
Description
C h a p t e r 1 2 Tr o u b l e s h o o t i n g
LED indicator status
CPU
Status
ERROR
FAULT
Stop
Blinking
Stop
ON
Stop
Blinking
Stop
ON
Stop
Blinking
Continue
Keep
Stop
ON
Continue
ON
Continue
ON
Stop
Keep
Stop
ON
Stop
ON
Stop
ON
Stop
ON
Continue
Blinking
Continue
Blinking
Stop
ON
Stop
ON
Stop
ON
Stop
ON
Stop
ON
Stop
ON
Stop
ON
Stop
ON
Stop
ON
Stop
ON
Continue
Keep
Stop
ON
Stop
ON
Stop
ON
Stop
ON
Stop
ON
Stop
ON
Stop
ON
Continue
Blinking
Continue
Blinking
BUS
Keep
Keep
Keep
Keep
Keep
Keep
Keep
Keep
Keep
ON
ON
Keep
Keep
Keep
Keep
Keep
Keep
Keep
Keep
Keep
Keep
Keep
Keep
Keep
Keep
Keep
Keep
Keep
Keep
Keep
Keep
Keep
Keep
Keep
Keep
Keep
1 2 - 6 3