12.4.10 AH10PFBS-5A

Error code
The node address of AH10PFBS-5A
16#A4F0
exceeds the valid range.
16#A4F1
Internal hardware error
16#A4F2
Parameter error
16#A4F3
Configuration error
16#A4F4
GPIO detection error
AH10PFBS-5A enters the mode of
16#A4F5
factory test.
1. AH10PFBS-5A has not been
connected to the PROFIBUS-DP
network.
2. PROFIBUS-DP master has not
16#A4F6
configured AH10PFBS-5A slave or
the configured node address of
AH10PFBS-5A is inconsistent with
that of the actually connected one.
Description
C h a p t e r 1 2 Tr o u b l e s h o o t i n g
LED indicator status
CPU
BUS FAULT
RUN
The green
The red light is ON.
light is ON.
The green
The red light is ON.
light is ON.
The green
The red light is ON.
light is ON.
The green
The red light is ON.
light is ON.
The green
The red light is ON.
light is ON.
The green
The red light is ON.
light is ON.
The green
The red light is ON.
light is ON.
Module
NET
The green
light is ON.
The green
light is ON.
The green
light is ON.
The green
light is ON.
The green
light is ON.
The green
light is ON.
The red light
is ON.
1 2 - 9 1