Serial
number
The master station reads the data in D2500~D2599 in the slave station whose station
#1
number is 2, and stores the data in D3000~D3099 in itself. Meanwhile, the data in
D3100~D3149 in the master station is written into D2600~D2649 in the slave station.
The master station reads the data in M3000~M3159 in the slave station whose station
#2
number is 2, and stores the data in M3000~M3159 in itself. Meanwhile, the data in
M3200~M3359 in the master station is written into M3200~M3359 in the slave station.
The master station reads the data in 16#1000~16#1018 in the slave station whose station
#4
number is 3, and stores the data in D3400~D3424 in itself. Meanwhile, the data in
D3500~D3524 in the master station is written into 16#1025~16#103D in the slave station.
The master station reads the data in D3000~D3099 in the slave station whose station
#5
number is 6, and stores the data in D3600~D3699 in itself. Meanwhile, the data in
D3700~D37999 in the master station is written into D3100~D3199 in the slave station.
Additional remark
If "Disabled" appears in the Status cell for a data exchange group, the data exchange group will not be
involved in data exchange, and the system will ignore the setting in other cells for the data exchange group.
Besides, if the setting of a data exchange group becomes incorrect after a modification, "Disabled" will
appear in the Status cell for the data exchange group.
B. Setting a Data Exchange Group
If users want to set the parameters for a data exchange group, they can double-click the data exchange
group in the data exchange table in the PLC Link Table Editor window.
C h a p t e r 11 C o n v e n i e n t F u n c t i o n s
Description
11 - 9