Download Print this page

Delta AH500 Hardware Operation Manual page 614

Hide thumbs Also See for AH500:

Advertisement

Error
code
The actual arrangement of the I/O modules is not
16#1402
consistent with the module table. (SM9)
An error occurs when the data is read from the module.
16#1403
(SM9)
The setting parameter of the module is not found.
16#1405
(SM9)
A communication error occurs when the data is
16#1407
accessed through the auxiliary processor. (SM9)
16#1409
The extension backplane is disconnected. (SM9)
The communication with the extension backplane is
16#140A
incorrect. (SM9)
The number of network modules exceeds the limit.
16#140B
(SM9)
The checksum of the high-speed data exchange is
16#140C
incorrect. (SM9)
The ID of the actual power supply module is not the
same as the ID of the power supply module set in
16#140D
HWCONFIG. (SM9)
The amount of data exchanged at a high speed
16#140E
exceeds the maximum amount supported. (SM10)
16#140F
High-speed data exchange error (SM11)
There is no interrupt service routine in the CPU
16#1801
module.
16#2000
There is no END in the program in the PLC. (SM5)
The program is incorrect. There is a syntax error.
16#2001
(SM5)
16#2002
GOEND is used incorrectly. (SM5)
The devices used in the program exceed the range.
16#2003
(SM0/SM5)
The part of the program specified by the label used in
16#2004
CJ/JMP is incorrect, or the label is used repeatedly.
(SM0/SM5)
The N value used in MC is not the same as the
corresponding N value used in MCR, or the number of
16#2005
N values used in MC is not the same as the number of
N values used in MCR. (SM5)
The N values used in MC do not start from 0, or the N
16#2006
values used in MC are not continuous. (SM5)
The operands used in ZRST are not used properly.
16#2007
(SM5)
16#200A
Invalid instruction (SM5)
The operand n or the other constant operands exceed
16#200B
the range. (SM0/SM5)
16#200C
The operands overlap. (SM0/SM5)
An error occurs when the binary number is converted
16#200D
into the binary-coded decimal number. (SM0/SM5)
16#200E
The string does not end with 0x00. (SM0/SM5)
The instruction does not support the modification by an
16#200F
index register. (SM5)
Description
C h a p t e r 1 2 Tr o u b l e s h o o t i n g
LED indicator status
CPU
Status
ERROR
Stop
Keep
Stop
Keep
Stop
Keep
Continue
ON
Stop
Keep
Stop
Keep
Stop
Keep
Stop
Keep
Stop
Keep
Stop
Keep
Stop
Keep
Continue
Keep
Stop
Blinking
Stop
Blinking
Stop
Blinking
Self-defined
Blinking
Stop
Blinking
Stop
Blinking
Stop
Blinking
Stop
Blinking
Stop
Blinking
Self-defined
Blinking
Self-defined
Blinking
Self-defined
Blinking
Self-defined
Blinking
Stop
Blinking
BUS
FAULT
ON
ON
ON
Keep
ON
ON
ON
ON
ON
ON
ON
Keep
Keep
Keep
Keep
Keep
Keep
Keep
Keep
Keep
Keep
Keep
Keep
Keep
Keep
Keep
1 2 - 6 5

Advertisement

loading