Classification
Model Name
module
AH08PTG-5A
AH04TC-5A
AH08TC-5A
AH02HC-5A
AH04HC-5A
AH05PM-5A
Motion control
AH10PM-5A
module
AH15PM-5A
AH20MC-5A
AH10EN-5A
AH15EN-5A
AH10SCM-5A
Network
module
AH15SCM-5A
AH10DNET-5A
AH10PFBM-5A
AH10PFBS-5A
AH10COPM-5A
AHRTU-DNET-5A
Remote I/O
AHRTU-PFBS-5A
module
AHRTU-ETHN-5A
Extension cable
AHACAB06-5A
Extension cable
AHACAB10-5A
Description
input impedance
Resolution: 0.1°C/0.1°F (16 bits)
Four-wire conversion time: 150 ms/channel
Three-wire conversion time: 300 ms/channel
Eight-channel four-wire/three-wire/two-wire RTD
Sensor type: Pt100/Pt1000/Ni100/Ni1000, and 0~300 Ω input
impedance
Resolution: 0.1°C/0.1°F (16 bits)
Conversion time: 20 ms/4 channels and 200 ms/8 channels
Four-channel thermocouple
Sensor type: J, K, R, S, T, E, N, and -150~+150 mV
Resolution: 0.1°C/0.1°F
Conversion time: 200 ms/channel
Eight-channel thermocouple
Sensor type: J, K, R, S, T, E, N, and -150~+150 mV
Resolution: 0.1°C/0.1°F
Conversion time: 200 ms/channel
Two-channel high-speed counter module (200 kHz)
Four-channel high-speed counter module (200 kHz)
Two-axis pulse train motion control module (1 MHz)
Six-axis pulse train motion control module
(Four axes: 1 MHz; Two axes: 200 kHz)
Four-axis pulse train motion control module (1 MHz )
Twelve-axis DMCNET (Delta Motion Control Network) motion
control module (10 Mbps)
It is an Ethernet communication module. It can function as a
mater or a slave. It is equipped with two Ethernet ports, and
supports a Modbus TCP master and EtherNet/IP (V2.0).
It is an Ethernet communication module. It can function as a
mater or a slave. It is equipped with two Ethernet ports, and
supports a Modbus TCP master and IEC60870-5-104.
It is a serial communication module with two RS-485/RS-422
ports, and supports Modbus and UD Link protocols.
One part of communication is isolated from the other part of the
communication, and one part of power is isolated from the other
part of the power.
It is a serial communication module with two RS-232 ports, and
supports Modbus and UD Link protocols.
One part of communication is isolated from the other part of the
communication, and one part of power is isolated from the other
part of the power.
It is a DeviceNet communication module. It can function as a
master or a slave. The maximum communication speed is 1
Mbps.
PROFIBUS-DP master module
PROFIBUS-DP slave module
It is a CANopen communication module. It can function as a
master or a slave.
DeviceNet remote I/O module
PROFIBUS-DP remote I/O module
Ethernet remote I/O module
0.6 meter extension cable for connecting an extension
backplane
1.0 meter extension cable for connecting an extension
C h a p t e r 1 I n t r o d u c t i o n
1 - 7

Advertisement

loading