The remaining number of PLC
16#757D
password guesses is 0.
The PLC password entered is
16#757E
incorrect.
The contents of the program
downloaded are incorrect.
16#8105
The program syntax is incorrect.
The contents of the program
downloaded are incorrect.
16#8106
The length of the execution code
exceeds the limit.
The contents of the program
downloaded are incorrect.
16#8107
The length of the source code
exceeds the limit.
A CPU parameter downloaded is
16#8230
incorrect. The IP address is illegal.
A CPU parameter downloaded is
16#8231
incorrect. The netmask address is
illegal.
A CPU parameter downloaded is
16#8232
incorrect. The gateway address is
illegal.
A CPU parameter downloaded is
16#8233
incorrect. The IP address filter is
set incorrectly.
A CPU parameter downloaded is
16#8235
incorrect. The static ARP table is
set incorrectly.
A CPU parameter downloaded is
16#8236
incorrect. The NTP client service is
set incorrectly.
A CPU parameter downloaded is
16#8239
incorrect. The email sending
function is set incorrectly.
A CPU parameter downloaded is
incorrect. The condition for the
16#823A
sending of an email is set
incorrectly.
A CPU parameter downloaded is
16#823B
incorrect. A TCP socket is set
incorrectly.
C h a p t e r 1 2 Tr o u b l e s h o o t i n g
Please power the CPU module again.
Please check whether the PLC password entered is
correct.
1. Check whether the program syntax which is not
supported by the CPU module is used, and check
whether the version of the firmware has its special
limitation.
2. Check whether the version of ISPSoft used to create
the program is the same as the version of ISPSoft
used now.
1. Shorten the length of the program, and download the
program again.
2. Check whether the version of ISPSoft used to create
the program is the same as the version of ISPSoft
used now.
1. Shorten the length of the program, and download the
program again.
2. Check whether the version of ISPSoft used to create
the program is the same as the version of ISPSoft
used now.
Please check the Ethernet parameters downloaded.
Please check the Ethernet parameters downloaded.
Please check the Ethernet parameters downloaded.
Please check the Ethernet parameters downloaded.
1. Check the Ethernet parameters for the CPU module
in HWCONFIG.
2. Check whether the version of HWCONFIG is
compatible with the version of the CPU module.
1. Check the Ethernet parameters for the CPU module
in HWCONFIG.
2. Check whether the version of HWCONFIG is
compatible with the version of the CPU module.
1. Check the Ethernet parameters for the CPU module
in HWCONFIG.
2. Check whether the version of HWCONFIG is
compatible with the version of the CPU module.
1. Check the Ethernet parameters for the CPU module
in HWCONFIG.
2. Check whether the version of HWCONFIG is
compatible with the version of the CPU module.
1. Check the Ethernet parameters for the CPU module
in HWCONFIG.
2. Check whether the version of HWCONFIG is
compatible with the version of the CPU module.
1 2 - 3 3