Data Formats and I/O Ranges
Range
Input Range
Code
Description
(hex)
100.00 Ω
Nickel RTD
29
α = .00392
0°C to 100°C
NOTE:
B-10 ADAM 4000 Series User's Manual
Data Formats
Engineering
Units
% of FSR
Twos
Complement
Ohms
* Resolution is one LSB of 16 bits
Maximum
Minimum
Specitied
Specitied
Signal
Signal
+100.00
+000.00
+100.00
+000.00
7FFF
0000
+200.64
+120.00
Displayed
Resolution
0.01°C
0.01%
1 LSB*
10 mΩ

Advertisement