Advantech Data Acquisition Modules ADAM 4000 User Manual page 253

Advantech data acquisition modules user's manual
Table of Contents

Advertisement

4050, 4051, 4052, 4053, 4055,
4056S, 4056SO, 4060, 4068, 4069
$AAF
Name
Read Firmware Version command
Description
The command requests the digital I/O module at address
AA to return the version code of its firmware
Syntax
$AAF (cr)
$
AA
address that you will access to.
F
(cr)
Response
!AA(Version)(cr)
There is no response if the module detects a syntax or
communication error, or even if the specified address does
not exist.
!
AA
address of the module.
(Version)
address AA.
(cr)
7-18 ADAM 4000 Series User's Manual
is a delimiter character.
(range 00-FF) represents the 2-character hexadecimal
is the Read Firmware Version command.
is the terminating character, carriage return (ODh).
if the command is valid.
is a delimiter character which indicates a valid command.
(range 00-FF) represents the 2-character hexadecimal
is the version code of the module's firmware at
is the terminating character, carriage return (ODh).