Advantech Data Acquisition Modules ADAM 4000 User Manual page 210

Advantech data acquisition modules user's manual
Table of Contents

Advertisement

4016
$AAS
Name
Start-up Voltage Output Configuration command
Description
Stores the present analog output value of the strain gauge
input module with address AA in the module's non-volatile
register. The output value will take effect upon start-up or
after a brownout.
Syntax
$AAS(cr)
$
AA
address of the strain gauge input module whose analog
output is to be set.
S
(cr)
Response
!AA(cr)
?AA(cr)
There is no response if the module detects a syntax error or
communication error or if the specified address does not
exist.
!
received.
?
AA
address of the strain gauge input module.
(cr)
NOTICE: A strain gauge input module requires a maximum of 6
milliseconds after it received a Startup Voltage Output
Configuration command to let the settings take effect. During
this interval, the module can not be addressed to perform any
other actions.
5-64
ADAM 4000 Series User's Manual
is a delimiter character.
(range 00-FF) represents the 2-character hexadecimal
is the Start-up Voltage Output Configuration command.
is the terminating character, carriage return (0Dh).
if the command is valid.
if an invalid command was issued.
delimiter character indicates a valid command was
delimiter character indicates the command was invalid.
(range 00-FF) represents the 2-character hexadecimal
is the terminating character, carriage return (0Dh).