4080, 4080D
$AAA
Name
Read Gate Mode command
Description
Request the specified counter/frequency module to return
its gate status.
Syntax
$AAA(cr)
$
AA
address that you will access to.
A
(cr)
Response
!AAG(cr)
There is no response if the module detects a syntax or
communication error, or even if the specified address does
not exist.
!
AA
address of the module.
G
G = 0 the gate is low
G = 1 the gate is high
G = 2 the gate is disabled.
(cr)
Example
command: $01A(cr)
response:
The command requests the counter/frequency module to
return its gate status. The module at address 01 replies with
gate setting high.
7-42 ADAM 4000 Series User's Manual
is a delimiter character.
(range 00-FF) represents the 2-character hexadecimal
is the Read Gate Mode command.
is the terminating character, carriage return (0Dh).
if the command is valid.
is a delimiter character which indicates a valid command.
(range 00-FF) represents the 2-character hexadecimal
determines the gate mode.
is the terminating character, carriage return (0Dh).
!011(cr)
Digital I/O and Relay Output
Counter/Frequency Command Set