4024
ADAM-4024 Command Review: (Continued)
Command Set
Function
$AA8Cn
Read Back CHn Output Range
$AAACnZ
Enable/Disable (Z=1/0) CHn EMS Flag
$AABCn
Read CHn EMS Flag
$AADCn
Read Back CHn StartUp Data
$AAECn
Read Back CHn Emergency Stop Data
$AAF
Read Firmware Version
$AAG
Reset Current Trim Data Variable To 0
$AAH
Read Current Trim Data Variable
$AAI
Read IDI
$AAM
Read Module Name
$AANCn
Read Back CHn 4mA Calibration
Parameter
$AAOCn
Read Back CHn 20mA Calibration
Parameter
$AAPCn
Clear CHn 4mA Calibration Parameter /
EEPROM
$AAQCn
Clear CHn 20mA Calibration Parameter /
EEPROM
$AAXnnnn
This command set the communication
watchdog timer (WDT) cycle time.
AA:
(range 00-FF) 2-character
hexadecimal address of the analog input
module which is to be read.
X:
the setting WDT command.
Nnnn:
value of communication cycle you want to
set. (Unit: 0.1 second)
$AAY
Read Communication Watchdog Timer
Cycle Setting.
AA:
(range 00-FF) 2-character
hexadecimal address of the analog input
module which is to be read.
Y:
the reading WDT cycle command.
6-21 ADAM 4000 Series User's Manual
(range 0000~9999) the specified
Response
Example
!AACnxx
$027C2
!AA
$02AC21
$02AC20
!AACn1
$02BC2
!AACn0
!AA(data)
$02DC2
!AA(data)
$02EC2
!AAAx.xx
$02F
!AA
$02G
!AAxx (xx=m)
$02H
!AAx
$02I
!AA4024
$02M
!AAxx
$02NC2
!AAxx
$02OC2
!AA
$02PC2
!AA
$02QC2
!AA
$02X1234
!AA
$02Y
6