SHIVER 900
Incorrect control unit set up
Error cause:
Probably there is an attempt to set up the control unit with an inadequate map.
NOTE: The instrument panel does not indicate the presence of this error even in the ATT status.
NOTE
THIS ERROR DISABLES THE TRACTION CONTROL.
Battery
Function
Provides electrical power to vehicle: the YTZ 12
BS battery is already activated, charged and
sealed;
Level in electrical circuit diagram:
Battery charge
Position:
on the vehicle: under the saddle
connector: on the battery
Electrical specifications:12 V / 10 Ah
Pin out:
1. Positive pole (red): approx. 12,6 V
2. negative pole (black): ground lead
DIAGNOSTIC TOOL:PARAMETERS
Battery voltage
Example value with key ON: 12.0 V
Example value with engine on: 14.2 V
This is one of the values set by the ECU in the
event of recovery mode
Battery voltage before prior to Recovery mode
Example value with key ON: 12.0 V
Example value with engine on: 14.2 V
Value determined from signal read without taking
considering whether recovery mode is implemen-
ted
CAUTION
BEFORE CARRYING OUT ANY TROUBLESHOOTING,
CAREFULLY READ THE GENERAL TROUBLESHOOTING
CONCEPTS FOR ELECTRICAL DEVICES AT THE BEGIN-
NING OF THE CHECK AND CONTROL SECTION IN THE
ELECTRICAL SYSTEM CHAPTER.
DIAGNOSTIC TOOL: LOGIC ERRORS
Electrical system
ELE SYS - 131

Hide quick links: