APRILIA SHIVER 900 Service Station Manual page 121

Table of Contents

Advertisement

SHIVER 900
Winding stage
Stage 1
Stage 2
Stage 3
Zero load voltage
Disconnect the three-way connector (1);
For a correct detection of the alternator voltage, a measurement must be carried out using
alternatively the 3 engine side connector pins: stage "1" (pin 1-2), stage "2" (pin 1-3), stage
"3" (pin 2-3)
Take the measurements;
If there is a significant difference between one stage and another (other than 15 V), this
means that the alternator is defective and must be replaced.
CAUTION
WITH THE ENGINE HOT THE VALUES RECORDED ARE ON AVERAGE 4-5 V LESS THAN THOSE
DETECTED WITH THE ENGINE COLD.
Vm linked voltage Reference values (V rms)
Short-circuit current
For a correct detection of the short-cir-
cuit current, a connector must be pre-
pared that generates a downstream
short circuit between the three alterna-
tor cables;
Start the engine and with an ammeter
clamp measure each single cable.
If there is a significant difference be-
tween the measure of the single cables
(other than 10 A), this means that the
alternator is defective and must be re-
placed.
CAUTION
WITH THE ENGINE HOT THE VALUES RECORDED ARE
ON AVERAGE 2-3 A LESS THAN THOSE DETECTED WITH
THE ENGINE COLD.
WARNING
NEVER KEEP THE ENGINE RUNNING FOR MORE THAN
ONE MINUTE; FAILURE TO DO SO COULD CAUSE SERI-
OUS OVERHEATING DAMAGES TO THE MOTORCYCLE
CIRCUITS.
R
ESISTANCE MEASUREMENT
Ambient temperature (ohm)
0.15 - 0.20
0.15 - 0.20
0.15 - 0.20
E
MPTY VOLTAGE
rpm
Afterwards heat stabilisation (ohm)
0.18 - 0.23
0.18 - 0.23
0.18 - 0.23
2000
6000
20 - 30
75 - 85
Electrical system
8000
95 - 105
ELE SYS - 121