Electrical system
TABLE F - PRE-ASSEMBLING THE ABS SUP-
PORT BRACKET
•
Pre-assemble the supports (1) for the
connectors on the ABS support brack-
et (2) and the seal (3).
TABLE G - PROCEDURE FITTING THE ABS CONTROL UNIT CONNECTOR CORRECTLY
•
The initial position of the connector coupling lever must be as indicated in the figures.
TABLE G1 - PROCEDURE FITTING THE ABS
CONTROL UNIT CONNECTOR CORRECTLY
•
Place the connector on the opposite
side of the control unit and lower the
driving lever until the "click" that signals
the end of the stroke is heard.
TABLE G2 - PROCEDURE FITTING THE ABS
CONTROL UNIT CONNECTOR CORRECTLY
•
When the connector has been inserted
fully, the distance measured between
it and the ABS control unit must be 7.5
mm
ELE SYS - 92
SHIVER 900