APRILIA SHIVER 900 Service Station Manual page 132

Table of Contents

Advertisement

Electrical system
P0560 Battery voltage
too high/too low
Error cause
If too high: too high a voltage has been detected at PIN 42. If too low: too low a voltage has
been detected at PIN 42.
The instrument cluster indicates the presence of this error with the MI warning light on fixed.
Troubleshooting
If too high: check that the voltage regulator is working correctly.
If too low: check voltage regulator connectors, engine-vehicle wiring harness connector and
ECU connector (check in particular for oxidation): if not OK, repair. If OK, check that resist-
ance of the Red/White cable from the voltage regulator connector to the ECU connector is
a few tenths of an Ohm; if not OK, repair the wiring harness. If OK, check that the alternator
is working correctly: if not OK, repair. If OK, check that the voltage regulator is working
correctly
P1560 Low battery voltage error - GCC error
Functional diagnosis:
low voltage
Error cause
The error is enabled if, after 5 seconds from the key to ON, the battery voltage is judged low
by the ECU.
Low voltage detected to PIN 52 of the Marelli ECU.
The presence of this error is signalled by the fixed lighting of the general warning light.
Troubleshooting
Try charging / replacing the battery: if NOT OK, carry out the check procedure for the alter-
nator connector and the control unit connector (paying particular attention to any oxidation):
if not OK, restore. If OK, check that cable resistance between the alternator cable and the
control unit is a few tenths of Ohm: if not OK, repair the wiring harness; if OK, check that the
alternator is working correctly: Restore if not OK.
NOTE
THE PRESENCE OF THIS ERROR DETERMINE THE DEACTIVATION OF THE TRACTION CON-
TROL AND THE CRUISE CONTROL.
ELE SYS - 132
SHIVER 900

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents