APRILIA SHIVER 900 Service Station Manual page 123

Table of Contents

Advertisement

SHIVER 900
3. Ground - Green/pink colour from the engine to
the clutch switch - Section 0.5
4. - Yellow/pink colour from the RH lights switch to
the 7SM control unit PIN 78 (engine stop) - Section
0.5
CAUTION
BEFORE CARRYING OUT ANY TROUBLESHOOTING,
CAREFULLY READ THE GENERAL TROUBLESHOOTING
CONCEPTS FOR ELECTRICAL DEVICES AT THE BEGIN-
NING OF THE CHECK AND CONTROL SECTION IN THE
ELECTRICAL SYSTEM CHAPTER.
DIAGNOSTIC TOOL: ELECTRICAL ERRORS
P0615 Starter relay
short circuit to positive / open circuit, short circuit to negative.
Error cause
Short-circuit to positive: excessive voltage identified at PIN 69, at the command time; If open
circuit, short circuit to negative: a voltage close to zero was identified when there is no
command to the start-up relay.
DIAGNOSTIC TOOL: LOGIC ERRORS
P0512 Starter switch
signal not plausible.
Error cause
Fault in the switch (lock) of the engine start-up. A continuous voltage close to 0 was detected
for a certain time (e.g. locked button).
The instrument panel does not indicate the presence of this error even in the ATT status.
Troubleshooting
Check the locking cause and restore.
Lights list
Front headlamp
Characteristic
Front daylight running light
12V - 5W x 2
Low beam light
12 V - 55 W H7
High beam light
12 V - 55 W H7
Electrical system