APRILIA SHIVER 900 Service Station Manual page 130

Table of Contents

Advertisement

Electrical system
P1606 Hardware and software incompatibility
Error cause
Incorrect engine control unit mapping
This error is indicated by lighting up in a fixed manner the general warning light.
Troubleshooting
Call the Help Desk
NOTE
THIS ERROR DETERMINES THE ENGINE STOP AN THE DEACTIVATION OF THE STARTER MO-
TOR.
P1607 Saved data file (for safety reasons)
Electrical diagnosis:
Filled
Error cause
This indication appears only if the Level 2 safety has reset the engine (C gravity).
The instrument panel does not indicate the presence of this error even in the ATT status
Troubleshooting
Perform the troubleshooting for the other detected errors.
P1650 Engine events configuration Checksum calculation error
Error cause:
Corrupt Flash-eeprom (hardware problem).
Upload (e.g. in service) of an incompatible software version, therefore missing the reference
check-sum.
This error is indicated by lighting up in a fixed manner the general warning light.
Troubleshooting:
Call the Help Desk.
Errori di errata configurazione
P1901 Ax acceleration sensor plausibility
Functional diagnosis:
Incorrect control unit set up
Error cause:
Probably there is an attempt to set up the control unit with an inadequate map.
NOTE: The instrument panel does not indicate the presence of this error even in the ATT status.
NOTE
THIS ERROR DISABLES THE TRACTION CONTROL.
P1902 Az acceleration sensor plausibility
Functional diagnosis:
ELE SYS - 130