SHIVER 900
Azzeramento icona manutenzione
The system displays the function as follows:
•
After the maintenance interval thresh-
olds are exceeded (excepting the first),
an icon with the adjustable wrench is
shown on the digital display.
To reset Service proceed as follows:
•
Connect the diagnostic tool;
•
Select the concerned model;
•
Enter in the "INSTRUMENT PANEL"
section;
•
Select "SELF-DIAGNOSIS";
•
Select "ACTIVATIONS";
•
Enable the command "SERVICE RE-
SET".
Battery recharge circuit
RECHARGING SYSTEM
•
Remove the tank and the filter casing;
•
Disconnect the three-way connector
(1) (white).
NOTE
THE ENGINE SIDE IS IDENTIFIED WITH THE LETTER "A"
Measurement of resistance (with engine off)
•
For a correct detection of the alternator
resistance, an ambient temperature
measurement must be carried out and
afterwards a heat stabilisation (after
turning fan on) by using a tester, using
alternatively the 3 connector pins:
stage "1" (pin 1-2), stage "2" (pin 1-3),
stage "3" (pin 2-3).
Electrical system
ELE SYS - 119