Side stand functional diagnosis:
up/down
Troubleshooting:
Indication on the diagnostic tool always down: perform the connector check procedure: if
not ok, restore; if ok, disconnect the two ends from the sensor and check the PIN 1 continuity
to ground: if there is no continuity, restore cable harness; if there is, replace the sensor
Indication on the diagnostic tool always up: disconnect the two ends from the sensor and
check if, with the stand down, there is continuity between the two PINS: if there is continuity
replace the sensor; if open circuit, it means that there is short circuit to ground of the brown/
green cable that goes from PIN 2 of the sensor to PIN 70 of the VEHICLE connector: restore
the wiring harness
Bank angle sensor
Function
indicates the vehicle position to the control unit.
Operation / Operating principle
When the sensor is in reverse position, the ground
circuit is closed: detecting this ground, the Marelli
control unit prevents the start-up or stops the en-
gine.
Level in electrical circuit diagram:start enable
switches
Position:
on the vehicle: under the saddle
connector: close to the sensor
Electrical specifications:
Vertical sensor: open circuit ( 62 kohm
resistance)
Reverse sensor: closed circuit (con-
tinuity)
Pin-out:
1. Voltage - Orange/Black colour, from VEHI-
CLE PIN 63 to the fall sensor, passing
through multiple connector - Section 0.5
Electrical system
ELE SYS - 179