APRILIA SHIVER 900 Service Station Manual page 272

Table of Contents

Advertisement

Engine
Replace the O-ring on the oil passage
duct.
Before refitting
UPON REFITTING THE CRANKSHAFT, GREASE THE SHAFT BUSHING-CONNECTING ROD
COUPLING.
Inspecting the crankshaft components
Checking crankshaft endfloat
The shaft axial clearance on the crank-
case should be checked with a dial
gauge mounted on the specific dial
gauge support.
The clearance should be between 0.10
and 0.26 mm (0.0039 - 0.0102 in).
If the clearance is beyond tolerance,
check the reference surfaces.
Specific tooling
020714Y Dial gauge mount
Main bearing journal
Removal
Mark the position of the original semi-bushings on the crankcase.
ENG - 272
SHIVER 900

Hide quick links: