THIS ERROR GENERATES THE RECOVERY STATUS AND ENGINE SHUT-DOWN.
P0605 ROM Error
Electrical diagnosis:
Circuit not functioning
Error cause:
Replace the injection control unit.
The instrument cluster indicates the presence of this error with the MI warning light on fixed.
NOTE
THIS ERROR GENERATES THE RECOVERY STATUS AND ENGINE SHUT-DOWN.
P060B A/D converter
Electrical diagnosis:
Circuit not functioning
Error cause:
Replace the injection control unit.
The instrument panel indicates this error by lighting up in a fixed manner the MI warning light and by
flashing the general warning light.
NOTE
THIS ERROR GENERATES THE RECOVERY STATUS AND ENGINE SHUT-DOWN.
DIAGNOSTIC TOOL: LOGIC ERRORS
P160C Level 2 safety reset
Error cause:
Due to the fact that the level 2 safety system (comparison between requested torque and
calculated torque) detected a fault, the control unit reset the engine (severity C).
The instrument panel does not indicate the presence of this error even in the ATT status.
Troubleshooting:
Perform the troubleshooting for the other detected errors
P060C Safety Engine Stop
Error cause:
Due to the fact that the safety system detected a serious fault, the control unit has stopped
the engine.
The instrument panel indicates this error by lighting up in a fixed manner the MI warning light and the
general warning light.
Troubleshooting:
Perform the troubleshooting for the other detected errors.
NOTE
THIS ERROR GENERATES THE RECOVERY STATUS AND ENGINE SHUT-DOWN.