APRILIA SHIVER 900 Service Station Manual page 116

Table of Contents

Advertisement

Electrical system
Electrical specifications
14 Ohm
Pin out
1. Grey colour, from the instrument panel to the
antenna - Section 0.5
2. Grey colour, from the instrument panel to the
antenna - Section 0.5
CAUTION
BEFORE CARRYING OUT ANY TROUBLESHOOTING,
CAREFULLY READ THE GENERAL TROUBLESHOOTING
CONCEPTS FOR ELECTRICAL DEVICES AT THE BEGIN-
NING OF THE CHECK AND CONTROL SECTION IN THE
ELECTRICAL SYSTEM CHAPTER.
INSTRUMENT PANEL: ERRORS
B0003 Immobilizer fault
key code read but not recognised
Error cause
The read code is not stored in the instrument panel memory
Troubleshooting
Carry out key data storage procedure
B0004 Immobilizer fault
read key code not read (key not present or transponder not working)
Error cause
Key transponder does not communicate its own code
Troubleshooting
Replace the key
B0005 Immobilizer fault
Immobilizer fault: aerial not working (open or short-circuited)
Error cause
An electric interruption or a ground short circuit or voltage to the circuit have been detected
Troubleshooting
Check the sensor connector on the cable harness and the instrument panel connector. If
not OK, restore; if OK, check electrical characteristics and aerial circuit continuity from the
instrument panel connector on PIN 2 and 3: if not OK, restore cable harness; if OK, check
circuit ground insulation: if not ground insulated, restore cable harness; if insulated, with key
ON, with instrument panel connector disconnected, check that there is not voltage at the
circuit ends: if there is voltage, restore the cable harness
B0006 Internal controller fault
ELE SYS - 116