TABLE G3 - PROCEDURE FITTING THE ABS
CONTROL UNIT CONNECTOR CORRECTLY
•
If the initial position of the lever is not
as indicated in the "TABLE G", the con-
nector will not couple correctly and the
distance measurement will be greater
(approx. 12 mm).
•
In this case, repeat the operation de-
scribed in "TABLES G1/G2"
•
We recommend creating a template in
order to ensure that the connector is
inserted correctly.
TABLE H - ABS CONTROL UNIT
•
After making sure that the ABS control
unit (2) connector (1) has been inser-
ted correctly, fasten the wiring harness
(3) to the brake pipes using two clamps
(4).
Electrical system